Summary0003165: Wrong variable data types in Program example
Description

Table A13 in part 10, version 1.03.02 specifies the type of FailureDetails to be Long. This does sound correct. String expected. Furthermore, Table A14 says data type node ID to have value Double, while table A13 speaks about Long.

TagsNo tags attached.
Commit Version
Fix Due Date

Activities

Karl Deiretsbacher

2016-10-18 13:14

developer   ~0007253

Fixed datatypes and replaced Table A.14 by description of the variables.

(note that this is just an example and a download program could return other or more variables as result)

Karl Deiretsbacher

2016-10-25 15:07

developer   ~0007273

Fixed in "OPC UA Part 10 - Programs 1.04.02 Draft Specification.docx".

Jim Luth

2016-10-25 16:12

administrator   ~0007281

Agreed to changes in telecon.

Issue History

Date Modified Username Field Change
2015-09-11 09:06 pfp.meijers New Issue
2016-08-18 04:01 randyarmstrong Project NodeSets, XSDs and Generated Code => 10000-010: Programs
2016-08-18 04:01 randyarmstrong Category Documentation Errata => Api Change
2016-08-30 15:43 Jim Luth Assigned To => Karl Deiretsbacher
2016-08-30 15:43 Jim Luth Status new => assigned
2016-10-18 13:14 Karl Deiretsbacher Note Added: 0007253
2016-10-25 15:07 Karl Deiretsbacher Note Added: 0007273
2016-10-25 15:07 Karl Deiretsbacher Status assigned => resolved
2016-10-25 15:07 Karl Deiretsbacher Fixed in Version => 1.04
2016-10-25 15:07 Karl Deiretsbacher Resolution open => fixed
2016-10-25 16:12 Jim Luth Note Added: 0007281
2016-10-25 16:12 Jim Luth Status resolved => closed
2016-10-25 17:20 Jim Luth Target Version => 1.04